WebChemScan® UV-2150/S Series Technical Specification1 FUNCTIONS AND OUTPUTS Measurement Principle High Resolution, Ultraviolet Absorbance via Optical Spectrometer Detector 256 Element Array Spectral Range 200 - 450 nm Calibration Technique Pattern Recognition of Spectral Data
WebChemScan ® UV -2150 Series TECHNICAL SPECIFICATION FUNCTIONS AND OUTPUTS Measurement Principle High Resolution, Ultraviolet Absorbance Number of Wavelengths 256 Spectral Range 200 - 450 nm Calibration Technique Pattern Recognition of Spectral Data Number of Parameters One
WebUV-2150/N ChemScan ChemScan An In-Situ Brand For On-Line and Real-Time Wastewater Analysis CAPABILITIES Continuous, On-Line, Automatic Monitoring ... ChemScan An In-Situ Brand "Monitoring a World of Water" www.ChemScan.com 2325 Parklawn Drive, Suite l, Waukesha, WI 53186 262-717-9500, Fax 262-717-9530 .
DA:29PA:62MOZ Rank:95
UV-2150/S Process Analyzer System - Environmental …
WebAnalyzer Description. The ChemScan UV-2150/S Analyzer is an on-line process-monitoring instrument. It has the capability of measuring multiple parameters including free ammonia, total ammonia, true monochloramine and total chlorine. The precise measurement of these parameters is critical for optimizing today’s advanced water treatment processes.
WebThe ChemScan UV‐Series Analyzer is an on‐line process‐monitoring instrument. It has the capability of measuring multiple parameters in a sample. The precise measurement of these parameters is critical for optimizing today’s advanced water treatment processes.
WebChemScan@ UV-2150/NoP ChemScan ChemScan An In-Situ Brand For On-Line and Real-Time Wastewater Analysis WASTEWATER NITRATE AND PHOSPHORUS CAPABILITIES Continuous, On-Line, Automatic Monitoring One or Two Sample Lines Two Parameter Analysis Analog, Serial or MODBUS Output Capabilities Multiple Alarms (Optional) Continual Self Diagnostics with Alarm
WebChemScan® UV-2150/N Series Technical Specification. High Resolution, Ultraviolet Absorbance 256 Element Array 200 - 450 nm Pattern Recognition of Spectral Data Nitrate and Ammonia Only Primary or Secondary Absorbance 4-20mA (4 outputs per sample line max.), RS-232, others optional 750 Values Time / Date Stamped, 24 Calibration Spectra YES ...
DA:51PA:98MOZ Rank:89
UV-2150/S ChemScan Analyzer for Chloramination Analysis
WebChemScan ® UV -2150/DC Series TECHNICAL SPECIFICATION FUNCTIONS AND OUTPUTS Measurement Principle High Resolution, Ultraviolet Absorbance Number of Wavelengths 256 Spectral Range 200 - 450 nm Calibrat ion Technique Pattern Recognition of Spectral Data Number of Parameters Two (special for de- chlorination monitoring)